Overview

The IR-276, NTP to IRIG-B Converter is designed to provide up to 16 customized IRIG-B outputs including 1PPS and NMEA-0183.
The IR-276 is synchronized from a NTP Server and functions as a NTP Client with multiple interface option. Our solution simultaneously supports IRIG-B (Mudulated / Unmodulated), NMEA 0183, 1PPS, and optical 1PPS port.

NTP to IRIG-B converter with 4 x IRIG-B outputs

The IR-276 NTP Client allows the user to assign up to 3 NTP Servers for redundant time synchronization. It selects the best available NTP Server based on criteria such as stratum level, jitter and wander, which ensures that the terminal equipment always remains synchronized to the best available time source. The IR-276 also helps isolate the terminal equipment from the perils of hacking and unlawful intrusions that are possible on an IP network.

Features

Selectable output modules

Up to 6 user (Add any 4 output cards, in any combination)

Un-Modulated outputs

Up to 16 x IRIG-B (RS422/RS232/BNC)

Modulated outputs

Up to 16 x IRIG-B (BNC)

NMEA-0183 outputs

Up to 8 x NMEA-0183

PPS outputs

Up to 16 x 1 PPS outputs (BNC) / Up to 4 x 1 PPS outputs (ST)

1 PPS accuracy to NTP Input

± 20us

Power Supply Options

AC/DC Power Supply options

Supported Protocols

Leap Second Correction Support

Highlights:

  • Synchronized to a Reference input a maximum of 3 NTP servers.
  • Serial Management Interface (USB) for local access.
  • Remote access over TCP-IP networks through SSH / Telnet. Allows the user to access and carry out maintenance remotely.
  • Password Controlled Access. Maintains a complete log of all logins.
  • 1U 19-inch rack mountable equipment.

Technical Specifications

PPS + NMEA output interface:
PPS + NMEA Outputs Number of interface Connector
PPS 2 outputs per card BNC
NMEA-0183 2 outputs per Card RJ45
Maximum cards Up to 4 outputs cards per Chassis 8 x BNC, 8 x RJ45
Maximum outputs 8 x PPS outputs & 8 x NMEA Outputs 8 x BNC, 8 x RJ45
PPS Output Interface:
PPS Output interface Number of Outputs Connector
1 PPS 4 outputs per card BNC
Maximum cards Up to 4 cards per chassis BNC
Maximum outputs 16 outputs per chassis BNC
IRIG-B (Un-modulated) output interfaces:
(Un-modulated) Output interface Number of Outputs Connector
IRIG-B (Un-modulated) Outputs 4 outputs per card BNC
Maximum cards Up to 4 cards per chassis 16 x BNC
Maximum outputs Up to 16 outputs per Chassis 16 x BNC
IRIG-B (Un-modulated RS422/RS485/RS232) output interfaces:
IRIG-B (Un-modulated) Output interface Number of Outputs Connector
IRIG-B (Un-modulated) Outputs RS422 Protocol 4 outputs per Card Terminal
Maximum outputs Up to 4 outputs per Chassis Terminal
Maximum outputs Up to 16 outputs per Chassis Terminal
IRIG-B (Modulated) output interfaces:
IRIG-B (Modulated) Output interface Number of Outputs Connector
IRIG-B (Modulated) Outputs 4 outputs per Card BNC
Maximum Cards Up to 4 outputs per Chassis BNC
Maximum outputs Up to 16 outputs per Chassis BNC
Optical Pulse card:
Optical Pulse Output interface Number of Outputs Connector
Optical Output 1 outputs per Card ST, 850nm, Multi-Mode
Maximum cards Up to 4 outputs per Chassis 4 x ST, 850nm, Multi-Mode
Maximum outputs Up to 4 outputs per Chassis 4 x ST, 850nm, Multi-Mode
Power Consumption:
  • < 10W at ambient (steady state 24°C)

Applications

NTP to IRIG-B Converter (NTP Client) Application Diagram
Application diagram showing the IR-276 NTP client port synchronized to an NTP Server and 4 x IRIG-B outputs synchronized to NTP timecode

Docs

Data Sheet (PDF)